Performance Plastics Process Systems
Search Catalog
      GO   
 Electronics    Furon® Q-Valve - Pneumatic Actuated 2-Way Diaphragm Valve (¼, ½, and ¾ inch Orifice)
Electronics > High Purity Valves > Standard High Purity Valves > Furon® Q-Valves > Furon® Q-Valve - Pneumatic Actuated 2-Way Diaphragm Valve (¼, ½, and ¾ inch Orifice) > Item # QV2-F1212-NC  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Item # QV2-F1212-NC, Furon® Q-Valves: Furon® Q-Valve - Pneumatic Actuated 2-Way Diaphragm Valve (¼, ½, and ¾ inch Orifice)



Our go-to valve offers a great combination of Cv, Pressure rating, cycling performance with the capability to have field maintenance done in a short period of time.

  • 2-Way configuration
  • Normally Closed or Normally Open operation
  • Superior cycling performance on aggressive chemicals such as HF & HCl or Slurry
  • Chemical & Slurry application
  • ¼”, ½”, ¾” Orifice
  • Cv exceeding 9.5
  • Field serviceable





 Specifications   

End Connection Type

FlareGrip® II

Orifice

3/4 in

End Connection Size

3/4 in

Dimension A

6.54 in
166.12
mm

Dimension B

0.97 in
24.60
mm

Dimension C

2.74 in
69.50
mm

Dimension D

6.09 in
154.00
mm

Operating Pressure

80 psig
5.5
bar

Back Pressure

80 psig
5.5
bar

Flow Factor (Cv)

9.40

Minimum Pilot Pressure

60 psig
4.1
bar

Maximum Pilot Pressure

100 psig
6.8
bar

Pilot Supply Port (FNPT)

1/8 in

Operating Temperature Range

59 to 182 ºF
15 to 82
ºC

Body Material

Ultra High Purity Perfluoroalkoxy Alkane (PFA)

Diaphragm Material

Modified Polytetrafluoroethylene (PTFE)

Actuator Component Material

Clear Polypropylene

Standard Flare Nut Material

Polyvinylidene Fluoride (PVDF)

Standard Options

  • Normally Open Version
  • Dual Actuation Version
  • PFA Flare Nuts

Features/Benefits

  • 100% Injection Molded High Purity PFA and Virgin PTFE wetted flow path
  • Integrated Visual Position Indication
  • Transparent actuation components
  • Bi-directional flow
  • Optional electronic position sensing
  • Leak Detection Port (1/4-28 UNF)
  • “Place and turn” integrated mounting base
  • Mounting pattern and port dimensions interchangeable with major competitors

Notes

  • Flow is calculated using QV2-F46-NC, QV2-F812NC, and QV2-F1216. When using smaller orifice connections flow will be reduced accordingly.


 MORE IMAGES 

·  Furon Q-Valve Pneumatic Drawing



 DOWNLOADS 

Furon Q-Valve Datasheet (Pneumatic)